Product Overview
The JJ VENT HRV-100-WSA provides wall-mounted single-room heat recovery ventilation in an anthracite finish, pairing the Ø100 mm through-wall ventilation kit with a matching two-speed wall switch. Its reversible fan alternates air extraction and intake through a ceramic regenerator to limit heat losses during ventilation.
Key Features
- Ceramic thermal regenerator with up to 85% heat recovery efficiency
- Ø100 mm nominal through-wall installation, anthracite finish
- Two selectable airflow rates: 20 / 24 m³/h (speed I / II)
- Recovery-mode airflow 10 / 12 m³/h (speed I / II)
- Low electrical consumption: 1.5 / 2.0 W (speed I / II)
- Included wall-mounted rocker switch for ON/OFF and speed I/II
- Automatic exhaust and supply phases, approximately 70 seconds each
- Telescopic duct 300–555 mm; IPX4 rating; washable EU1 filters
Technical Specifications
| Model | JJ VENT HRV-100-WSA |
|---|---|
| Type | Single-room through-wall heat recovery ventilator |
| Nominal size | Ø100 mm |
| Finish | Anthracite |
| Control | Included two-speed wall switch (OFF/ON, I/II) |
| Supply voltage | 220–240 V AC, 50 Hz |
| Airflow — Speed I / II | 20 / 24 m³/h |
| Heat recovery mode airflow — Speed I / II | 10 / 12 m³/h |
| Power consumption — Speed I / II | 1.5 / 2.0 W |
| Sound pressure at 3 m — Speed I / II | 27 / 32 dB(A) |
| Fan rotation — Speed I / II | 2050 / 2450 rpm |
| Heat recovery efficiency | Up to 85% (manufacturer-stated) |
| Ingress protection | IPX4 |
| Filter classification | EU1 |
| Energy efficiency class | A (manufacturer-stated) |
| Ambient operating temperature | −30 to +50 °C |
| Unit weight | 1.54 kg |
Dimensions
| A | 140 mm |
|---|---|
| B — Adjustable duct length | 300–555 mm |
| C | 81 mm |
| ØD | 106 mm |
| E | 153 mm |
| F | 148 mm |
Construction & Installation
Kit comprises axial fan, ceramic heat regenerator, airflow straightener, two EU1 filters, adjustable telescopic duct, exterior grille and two-speed wall switch. Install through an exterior wall with approximately 1–2° outward downward duct slope. Electrical installation must be carried out by a qualified electrician, following the supplied documentation and the actual product terminal markings.
Downloads
- Technical Datasheet — HRV-100-WSA (PDF)
- Installation & User Manual — English (PDF)
- Installation & User Manual — 15 Languages (PDF)
Specifications are based on supplier technical documentation and are subject to change; verify before installation. Product photos may include small original component markings.
Authenticité garantie
- Choisir une sélection entraîne un rafraîchissement complet de la page.
- Ouvre dans une nouvelle fenêtre.